Описание оборудования | |
---|---|
Distance sensor | |
General specifications | |
Measurement range | 100 ... 300 mm |
Reference target | standard white, 100 mm x 100 mm |
Light source | LED |
Light type | modulated visible red light |
LED risk group labelling | exempt group |
Angle deviation | max. +/- 1.5 ° |
Diameter of the light spot | approx. 8 mm at a distance of 300 mm |
Angle of divergence | 1.8 ° |
Ambient light limit | EN 60947-5-2 : 45000 Lux |
Resolution | 0.1 mm |
Functional safety related parameters | |
MTTFd | 520 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
Function indicator | LED yellow: constantly on - switch output active constantly off - switch output inactive |
Control elements | Teach-In key |
Control elements | 5-step rotary switch for operating modes selection |
Electrical specifications | |
Operating voltage | 18 ... 30 V DC |
Ripple | max. 10 % |
No-load supply current | < 25 mA at 24 V supply voltage |
Protection class | III |
Interface | |
Interface type | IO-Link ( via C/Q = pin 4 ) |
Device profile | Identification and diagnosis Smart Sensor type 0/type 3.3 |
Transfer rate | COM2 (38.4 kBaud) |
IO-Link Revision | 1.1 |
Min. cycle time | 3 ms |
Process data witdh | Process data input 4byte Process data output 2bits |
SIO mode support | yes |
Device ID | 0x111906 (1120518) |
Compatible master port type | A |
Output | |
Switching type | The default setting is: C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link U—Pin2: analog output 0 ... 10 V |
Signal output | 1 push-pull output , 1 analog output , short-circuit-proof, reverse polarity protection, surge-proof |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA , resistive load |
Usage category | DC-12 and DC-13 |
Voltage drop | ? 1.5 V DC |
Response time | 2 ms , see table 1 |
Analog output | |
Output type | 1 voltage output: 0 ... 10 V |
Load resistor | > 1 k? voltage output ; ? 470 ? current output |
Conformity | |
Communication interface | IEC 61131-9 |
Product standard | EN 60947-5-2 |
Measurement accuracy | |
Temperature drift | 0.05 %/K |
Warm up time | 5 min |
Repeat accuracy | < 0.5 % , see table 1 |
Li |